|   64 Port Plus E1 Monitoring Groomer   |

|   PRODUCTS   |

Description

The VCL-MegaConnect, 64 Port Plus - E1 Monitoring Groomer is suitable for non-intrusive monitoring of upto 32, "live" E1 traffic links, bidirectionally (i.e. in both transmit and receive directions through its 64 E1 receivers) through a high impedance (Hi-Z) path. Additionally, the equipment also provides 16 output E1 ports that shall connect the aggregated time-slots which have been non-intrusively "monitored" from the 32, "live" E1 traffic links to the user's protocol analysers, test probes, etc.

The VCL-MegaConnect, 64 Port Plus - E1 Monitoring Groomer, occupies only a 3U high rack-space, and is a compact 19-inch stand-alone unit. The unit is powered by and operates on a dual (1+1 protected) -48V DC power supply. An AC mains option is also available with an external AC-DC converter.

64 Port Plus E1 Hi-Z Monitoring Groomer - Data Sheet (PDF)

The equipment is provided with BOTH, RS232 Serial Interface for COM Port connection and as well as a TCP/IP LAN Interface (10BaseT) for providing equipment access through Telnet over a LAN/TCI/IP link. The user may select and use either of these ports for executing HyperTerminal text commands for configuration etc. The access for configuration and system management is provided through CLI (Command Line Interface) text commands which may be executed either from a serial (COM) Port of a PC or through the TCP/IP 10/100BaseT LAN Interface. The 10/100BaseT LAN Interface allows the equipment to be connected on a TCP/IP network for remote access for configuration and monitoring over LAN/TCP/IP link. The system is also supplied with an easy to use Windows (95, 98, Me, XP) Graphical User Interface that provides the user a complete control to prepare multiple configuration "maps" and store them as easy to read data files. Dry contact relay alarm output is also available at rear of the system to connect the system to an external audio/visual alarm output though a dry relay contact.

The Groomer is capable of non-intrusively monitoring upto 32 "live" E1 links and grooming the selected 64 Kbps time-slots to the 16 additional output E1 Ports provided in the equipment. The 64, E1 receivers of the Groomer shall connect to the 32, E1 "live traffic" links which are to be monitored, non-Intrusively. 16 additional (Normal-Z) output E1 Ports are also provided by the equipment which shall route the aggregated data of the "monitored" time-slots to the userís test equipment, such as protocol analysers, test probes, billing servers etc.

The Groomer (E1 Monitoring DACS) is capable of monitoring a -20dBdsx (0.3Volt Pulse) E1 signal through a Hi-Z path, without in any way affecting or disturbing the "live" E1 traffic that is required to be monitored.

The equipment offers the user with complete flexibility to choose and select time-slots from each of the 32 E1 links that are being monitored, without limitation or restrictions, through the internal TSI non-blocking switch (data received by the equipment's 64 E1 receivers) and then aggregate the selected time-slots to the 16 output E1 ports that shall connect to the test probes etc.

Application Diagram

The additional solutions are offered and available for Hi-z non-intrusive live traffic monitoring applications are:

  • The scalable 64 Port Plus T1 Monitoring Groomer provides upto 32 T1 links (64 T1 Ports) plus 16 additional spare T1 ports (Normal-Z) to connect to the measurement-probe, billing servers etc.

  • The 16 Port Plus T1 Monitoring Groomer provides upto 8 T1 links (16 T1 Ports) plus 4 additional spare T1 ports (Normal-Z) to connect to the measurement-probe, billing servers etc.

  • The 16 Port Plus E1 Monitoring Groomer provides upto 8 E1 links (16 E1 Ports) plus 4 additional spare E1 ports (Normal-Z) to connect to the measurement-probe, billing servers etc.

  • The 32 Port Plus E1 Monitoring Groomer provides upto 16 E1 links (32 E1 Ports) plus 4 additional spare E1 ports (Normal-Z) to connect to the measurement-probe, billing servers etc.

  • The 32 Port Plus T1 Monitoring Groomer provides upto 16 T1 links (32 T1 Ports) plus 4 additional spare T1 ports (Normal-Z) to connect to the measurement-probe, billing servers etc.

Indications and Alarm Monitoring

  • Loss of incoming signal at any E1 Port
  • Configuration Error Alarm
  • Clock Status
  • 1 to 64 E1 Ports - LED indicators to indicate the status of each E1 Monitoring Port
  • 1 to 16 E1 Ports - LED indicators to indicate the status of each E1 Test Port
  • +3 Volts Power Supply
  • -48V DC Input Voltage present
  • Configuration Error.

Programmable Features

  • Specifying the priority sequence for clock selection
  • Enabling or Disabling E1 Ports (masking) of the E1 Ports that are not in use
  • Creating a cross connect between E1s at DS-O level (single time-slot level) using the CLI text commands or Windows based GUI
  • Telnet interface for remote programming.

Status Monitoring

  • Clock Selection
  • Status of alarms
  • Enabled/Disabled status of E1 Ports
  • Monitoring of the VCL-MegaConnect E1 64 Port Groomer, status and configuration.

Others Links:

  Multiplexers
  STM SDH Multiplexers
  E1 VoIP-GSM Gateways
  VoIP SS7 and C7 Solution
  Echo Cancellers and VQE Solutions
  GSM Gateways / GSM Channel Banks
  E1 and T1 over Ethernet (TDM over IP)
  Groomers (Hi-Z Non-Intrusive Monitoring)
  Digital Access Cross Connect Switch (DACS)
  E1, T1, E3, DS3, Ethernet Converter (IP over TDM)

Technical specifications are subject to change without notice.
All brand names and trademarks are the property of their respective owners.